6000 watt laser cutting machine supplier widely used in various industries such as automotive, aerospace, electronics and manufacturing. They are particularly suitable for applications that require high precision and quality, such as prototyping, manufacturing and the production of complex parts. The Fiber Laser Cutting Machine indispensable tool in modern manufacturing, providing unparalleled precision and efficiency in material processing. 6000 watt laser cutting machine provides excellent beam quality, allowing very precise cutting with minimal heat-affected zone. They are highly efficient and convert electrical energy into laser power at a much higher rate than other types of lasers. The Fiber Laser Cutting Machine is almost no moving parts and the maintenance cost is extremely low. They can cut a variety of materials, including metals such as stainless steel, aluminum and copper, as well as non-metals such as plastics and wood.
Maintenance of fiber laser cutting machine
- Lens cleaning: Regularly check and clean the protective lens and focusing lens on the laser cutting head, gently wipe with anhydrous ethanol to remove dust and other contaminants to prevent laser loss or lens damage.
- Water tank cleaning: Check and regularly replace the circulating water in the cooler. It is recommended to replace it every six months or before long-term non-use to ensure that the water quality and water temperature are suitable.
- Fan cleaning: Clean the dust in the fan and air duct regularly, at least once a month, to ensure the dust removal and deodorization effect.
- Guide rail cleaning: Clean the dust on the guide rail and frame regularly, at least once a month, to maintain the processing accuracy of the equipment.
- Screw and coupling maintenance: Check the transmission parts regularly for abnormal noise or phenomena, and adjust and maintain them in time, and check them once a month.
- Daily inspection: Check the pressure of the laser working gas and cutting gas before starting the machine every day, ensure that the zero point and limit switches of each axis are working normally, check the circulating water level and add it in time, and check whether there is leakage in the external optical path circulating water.
- Optical lens maintenance: Avoid touching the lens directly with your hands, use special cleaning cloth and anhydrous ethanol to clean, avoid using water or detergent to prevent damage to the lens surface.
- Air compressor maintenance: Drain regularly, clean the air filter, replace the filter element, and check the lubrication of the crankshaft bearing.
- Water replacement and water tank cleaning: It is recommended to clean the water tank and replace the circulating water at least once a week. Use purified water and control the water temperature below 35°C. If the water temperature exceeds 35°C, replace the circulating water or add ice cubes.